PRODUCTS

Erline & Data Transmission Cables

Data Transmission Cables

Data transmission is the process of transfer data over a point-to-point or point-to-multipoint communication channel, like a communication medium to one or more computing, network, communication or electronic devices. Data transmission is also known as digital transmission or digital communications. The data are represented as an electromagnetic signal, such as an electrical voltage, radiowave, microwave, or infrared signal.

Data transfer rate is commonly measured in bits-per-second (bps), with one “bit” equal to an individual binary number. A wide range of different constructions of cables are available in order to cover data transmission needs in automation systems, computer networks and electronic control systems.

» Local Area Network Cables:

It is a computer network that links devices within a building or group of adjacent buildings, simply referred to as LAN Cables.
Computer networks, which provide the productivity and communication capabilities that will enable organizations to be successful, have now become the most important elements. Data transmission is significant for growing businesses, institutions and service providers to be able to build scalable networks that combine voice, video, data transfer and storage on an end-to-end intelligent network. All communication over a single infrastructure offers several advantages such as reduced costs, increased productivity and efficiency, elimination of the complexity of using separate networks, and scalability.

In order for the network systems to work fast and without problems, the cabling infrastructure must be well established. In network systems, there is no other interface that is used as long as the cabling infrastructure. The main reason for the preparation of structured cabling systems is to ensure that the network system grows without any problems. For this reason, a correct design and project should be done while creating the cabling infrastructure, quality workmanship and materials should be used, testing, labeling and documentation should be made in accordance with the standards and used for years.

There are generally three levels in structured cabling.
1. Floor distribution cabling (horizontal cabling)
2. Building distribution cabling (vertical cabling)
3. Campus (main) distribution cabling

ERLINE® branded Cat-5e U/UTP and Cat-6 U/UTP copper conductor data transmission cables that we produce as Erse Kablo are generally used in the horizontal cabling section of structured cabling. ERLINE® ethernet cables have been manufactured and certified according to IEC 61156-1 & -5 and ANSI/TIA 568-C.2.

» RS-485 Data Transmission Cables:

It is defined by EIA (USA Electronic Industry Association) as a two serial communication standard and more correctly named as EIA/TIA-485. Communication systems based on RS-485 communicate digital information over twisted pair wire from transmitters to receivers. Devices can be apart from each other up to 1220 meters without any repeaters and 32 RS-485 transceivers (32 drivers 32 receivers) can occupy a bus and communicate at rate from 100Kbps (at 1200 m) up to 10Mbps (at 12 m) varying by cable length. These systems utilize balanced outputs and differential inputs. As a result, they provide better noise immunity than single-ended systems such as RS-232. Thus, links using RS-485 operate over longer distance at higher speed than links using RS 232. RS-485 can be used in two and four-wire networked systems and tri-state capabilities of RS-485 transmitters enable multiple transceivers to be connected to a two-wire multidrop bus. Also, four-wire systems can be used master node driver to be connected to all slave receivers and all slave drivers to be connected to master receiver.

» Bus Data Transmission Cables:

Profibus is a data transmission system of host computer and other computers, sensors, motors, thermocouples, automatic valves which are parts of scada* system on a single line whereby high data speed, low connection costs and plug-and-play are central. It refers to the network protocols used for real-time distributed control. (*A generic name for systems that allow inspection, monitoring and operating under a logic of devices sprawling over a wide geographical area from a center by means of computers.)

There are two standard versions of BUS cables being producing in Erse Kablo. One of them is Profibus DP which stands for Decentralised Peripherals and the other is Profibus PA which stands for Process Automation.

Erse's Data Transmission Cable Solutions for the Customer Expectations

Our data transmission cables are produced for use in high-speed applications. It is focused on achieving the best possible electrical values.

Data Transmission Cables which have HFFR (Halogen Free Flame Retardant) sheathing are used in places where people are densely populated (such as hospitals, high residences, shopping centers, hotels etc.) and places in which it is required that there is no smoke and corrosive gases emitted by fire which threats to human health.

We are at your disposal for your demands; you could have best data transmission cable price from our export sales team and our technical team would be pleased to answer your questions about technical points. We will be happy to advise you on our product range and the possible applications of Erse’s data transmission cables. You can contact us with e-mail or head office’s telephone numbers.
ERLINE CAT-6 U/UTP
ERLINE CAT-6 U/UTP
ERLINE CAT-6 U/UTP LSZH
ERLINE CAT-6 U/UTP LSZH
ERLINE CAT-6 F/UTP
ERLINE CAT-6 F/UTP
ERLINE CAT-6 F/UTP LSZH
ERLINE CAT-6 F/UTP LSZH
LIY(St)Y PIMF
LIY(St)Y PIMF
LIY(St)CY PIMF
LIY(St)CY PIMF
LI2Y(St)Y PIMF
LI2Y(St)Y PIMF
LI2Y(St)CY PIMF
LI2Y(St)CY PIMF
LI2Y(St)CH PIMF
LI2Y(St)CH PIMF
LI2Y(St)H PIMF
LI2Y(St)H PIMF
LIH(St)H PIMF
LIH(St)H PIMF
LIH(St)CH PIMF
LIH(St)CH PIMF
LI2Y(St)CY PIMF (RS 232 - RS 422)
LI2Y(St)CY PIMF (RS 232 - RS 422)
LI2Y(St)CY (RS 485)
LI2Y(St)CY (RS 485)
PROFIBUS-DP
PROFIBUS-DP
PROFIBUS-PA
PROFIBUS-PA
EIB-2Y(St)Y
EIB-2Y(St)Y
EIB-H(St)H
EIB-H(St)H
Erse Kablo
  Language
PRODUCTS

Erline & Data Transmission Cables

Data Transmission Cables

Data transmission is the process of transfer data over a point-to-point or point-to-multipoint communication channel, like a communication medium to one or more computing, network, communication or electronic devices. Data transmission is also known as digital transmission or digital communications. The data are represented as an electromagnetic signal, such as an electrical voltage, radiowave, microwave, or infrared signal.

Data transfer rate is commonly measured in bits-per-second (bps), with one “bit” equal to an individual binary number. A wide range of different constructions of cables are available in order to cover data transmission needs in automation systems, computer networks and electronic control systems.

» Local Area Network Cables:

It is a computer network that links devices within a building or group of adjacent buildings, simply referred to as LAN Cables.
Computer networks, which provide the productivity and communication capabilities that will enable organizations to be successful, have now become the most important elements. Data transmission is significant for growing businesses, institutions and service providers to be able to build scalable networks that combine voice, video, data transfer and storage on an end-to-end intelligent network. All communication over a single infrastructure offers several advantages such as reduced costs, increased productivity and efficiency, elimination of the complexity of using separate networks, and scalability.

In order for the network systems to work fast and without problems, the cabling infrastructure must be well established. In network systems, there is no other interface that is used as long as the cabling infrastructure. The main reason for the preparation of structured cabling systems is to ensure that the network system grows without any problems. For this reason, a correct design and project should be done while creating the cabling infrastructure, quality workmanship and materials should be used, testing, labeling and documentation should be made in accordance with the standards and used for years.

There are generally three levels in structured cabling.
1. Floor distribution cabling (horizontal cabling)
2. Building distribution cabling (vertical cabling)
3. Campus (main) distribution cabling

ERLINE® branded Cat-5e U/UTP and Cat-6 U/UTP copper conductor data transmission cables that we produce as Erse Kablo are generally used in the horizontal cabling section of structured cabling. ERLINE® ethernet cables have been manufactured and certified according to IEC 61156-1 & -5 and ANSI/TIA 568-C.2.

» RS-485 Data Transmission Cables:

It is defined by EIA (USA Electronic Industry Association) as a two serial communication standard and more correctly named as EIA/TIA-485. Communication systems based on RS-485 communicate digital information over twisted pair wire from transmitters to receivers. Devices can be apart from each other up to 1220 meters without any repeaters and 32 RS-485 transceivers (32 drivers 32 receivers) can occupy a bus and communicate at rate from 100Kbps (at 1200 m) up to 10Mbps (at 12 m) varying by cable length. These systems utilize balanced outputs and differential inputs. As a result, they provide better noise immunity than single-ended systems such as RS-232. Thus, links using RS-485 operate over longer distance at higher speed than links using RS 232. RS-485 can be used in two and four-wire networked systems and tri-state capabilities of RS-485 transmitters enable multiple transceivers to be connected to a two-wire multidrop bus. Also, four-wire systems can be used master node driver to be connected to all slave receivers and all slave drivers to be connected to master receiver.

» Bus Data Transmission Cables:

Profibus is a data transmission system of host computer and other computers, sensors, motors, thermocouples, automatic valves which are parts of scada* system on a single line whereby high data speed, low connection costs and plug-and-play are central. It refers to the network protocols used for real-time distributed control. (*A generic name for systems that allow inspection, monitoring and operating under a logic of devices sprawling over a wide geographical area from a center by means of computers.)

There are two standard versions of BUS cables being producing in Erse Kablo. One of them is Profibus DP which stands for Decentralised Peripherals and the other is Profibus PA which stands for Process Automation.

Erse's Data Transmission Cable Solutions for the Customer Expectations

Our data transmission cables are produced for use in high-speed applications. It is focused on achieving the best possible electrical values.

Data Transmission Cables which have HFFR (Halogen Free Flame Retardant) sheathing are used in places where people are densely populated (such as hospitals, high residences, shopping centers, hotels etc.) and places in which it is required that there is no smoke and corrosive gases emitted by fire which threats to human health.

We are at your disposal for your demands; you could have best data transmission cable price from our export sales team and our technical team would be pleased to answer your questions about technical points. We will be happy to advise you on our product range and the possible applications of Erse’s data transmission cables. You can contact us with e-mail or head office’s telephone numbers.
ERLINE CAT-6 U/UTP
ERLINE CAT-6 U/UTP
ERLINE CAT-6 U/UTP LSZH
ERLINE CAT-6 U/UTP LSZH
ERLINE CAT-6 F/UTP
ERLINE CAT-6 F/UTP
ERLINE CAT-6 F/UTP LSZH
ERLINE CAT-6 F/UTP LSZH
LIY(St)Y PIMF
LIY(St)Y PIMF
LIY(St)CY PIMF
LIY(St)CY PIMF
LI2Y(St)Y PIMF
LI2Y(St)Y PIMF
LI2Y(St)CY PIMF
LI2Y(St)CY PIMF
LI2Y(St)CH PIMF
LI2Y(St)CH PIMF
LI2Y(St)H PIMF
LI2Y(St)H PIMF
LIH(St)H PIMF
LIH(St)H PIMF
LIH(St)CH PIMF
LIH(St)CH PIMF
LI2Y(St)CY PIMF (RS 232 - RS 422)
LI2Y(St)CY PIMF (RS 232 - RS 422)
LI2Y(St)CY (RS 485)
LI2Y(St)CY (RS 485)
PROFIBUS-DP
PROFIBUS-DP
PROFIBUS-PA
PROFIBUS-PA
EIB-2Y(St)Y
EIB-2Y(St)Y
EIB-H(St)H
EIB-H(St)H
  Language
Erse Kablo
PRODUCTS

Erline & Data Transmission Cables

Data Transmission Cables

Data transmission is the process of transfer data over a point-to-point or point-to-multipoint communication channel, like a communication medium to one or more computing, network, communication or electronic devices. Data transmission is also known as digital transmission or digital communications. The data are represented as an electromagnetic signal, such as an electrical voltage, radiowave, microwave, or infrared signal.

Data transfer rate is commonly measured in bits-per-second (bps), with one “bit” equal to an individual binary number. A wide range of different constructions of cables are available in order to cover data transmission needs in automation systems, computer networks and electronic control systems.

» Local Area Network Cables:

It is a computer network that links devices within a building or group of adjacent buildings, simply referred to as LAN Cables.
Computer networks, which provide the productivity and communication capabilities that will enable organizations to be successful, have now become the most important elements. Data transmission is significant for growing businesses, institutions and service providers to be able to build scalable networks that combine voice, video, data transfer and storage on an end-to-end intelligent network. All communication over a single infrastructure offers several advantages such as reduced costs, increased productivity and efficiency, elimination of the complexity of using separate networks, and scalability.

In order for the network systems to work fast and without problems, the cabling infrastructure must be well established. In network systems, there is no other interface that is used as long as the cabling infrastructure. The main reason for the preparation of structured cabling systems is to ensure that the network system grows without any problems. For this reason, a correct design and project should be done while creating the cabling infrastructure, quality workmanship and materials should be used, testing, labeling and documentation should be made in accordance with the standards and used for years.

There are generally three levels in structured cabling.
1. Floor distribution cabling (horizontal cabling)
2. Building distribution cabling (vertical cabling)
3. Campus (main) distribution cabling

ERLINE® branded Cat-5e U/UTP and Cat-6 U/UTP copper conductor data transmission cables that we produce as Erse Kablo are generally used in the horizontal cabling section of structured cabling. ERLINE® ethernet cables have been manufactured and certified according to IEC 61156-1 & -5 and ANSI/TIA 568-C.2.

» RS-485 Data Transmission Cables:

It is defined by EIA (USA Electronic Industry Association) as a two serial communication standard and more correctly named as EIA/TIA-485. Communication systems based on RS-485 communicate digital information over twisted pair wire from transmitters to receivers. Devices can be apart from each other up to 1220 meters without any repeaters and 32 RS-485 transceivers (32 drivers 32 receivers) can occupy a bus and communicate at rate from 100Kbps (at 1200 m) up to 10Mbps (at 12 m) varying by cable length. These systems utilize balanced outputs and differential inputs. As a result, they provide better noise immunity than single-ended systems such as RS-232. Thus, links using RS-485 operate over longer distance at higher speed than links using RS 232. RS-485 can be used in two and four-wire networked systems and tri-state capabilities of RS-485 transmitters enable multiple transceivers to be connected to a two-wire multidrop bus. Also, four-wire systems can be used master node driver to be connected to all slave receivers and all slave drivers to be connected to master receiver.

» Bus Data Transmission Cables:

Profibus is a data transmission system of host computer and other computers, sensors, motors, thermocouples, automatic valves which are parts of scada* system on a single line whereby high data speed, low connection costs and plug-and-play are central. It refers to the network protocols used for real-time distributed control. (*A generic name for systems that allow inspection, monitoring and operating under a logic of devices sprawling over a wide geographical area from a center by means of computers.)

There are two standard versions of BUS cables being producing in Erse Kablo. One of them is Profibus DP which stands for Decentralised Peripherals and the other is Profibus PA which stands for Process Automation.

Erse's Data Transmission Cable Solutions for the Customer Expectations

Our data transmission cables are produced for use in high-speed applications. It is focused on achieving the best possible electrical values.

Data Transmission Cables which have HFFR (Halogen Free Flame Retardant) sheathing are used in places where people are densely populated (such as hospitals, high residences, shopping centers, hotels etc.) and places in which it is required that there is no smoke and corrosive gases emitted by fire which threats to human health.

We are at your disposal for your demands; you could have best data transmission cable price from our export sales team and our technical team would be pleased to answer your questions about technical points. We will be happy to advise you on our product range and the possible applications of Erse’s data transmission cables. You can contact us with e-mail or head office’s telephone numbers.
ERLINE CAT-6 U/UTP
ERLINE CAT-6 U/UTP
ERLINE CAT-6 U/UTP LSZH
ERLINE CAT-6 U/UTP LSZH
ERLINE CAT-6 F/UTP
ERLINE CAT-6 F/UTP
ERLINE CAT-6 F/UTP LSZH
ERLINE CAT-6 F/UTP LSZH
LIY(St)Y PIMF
LIY(St)Y PIMF
LIY(St)CY PIMF
LIY(St)CY PIMF
LI2Y(St)Y PIMF
LI2Y(St)Y PIMF
LI2Y(St)CY PIMF
LI2Y(St)CY PIMF
LI2Y(St)CH PIMF
LI2Y(St)CH PIMF
LI2Y(St)H PIMF
LI2Y(St)H PIMF
LIH(St)H PIMF
LIH(St)H PIMF
LIH(St)CH PIMF
LIH(St)CH PIMF
LI2Y(St)CY PIMF (RS 232 - RS 422)
LI2Y(St)CY PIMF (RS 232 - RS 422)
LI2Y(St)CY (RS 485)
LI2Y(St)CY (RS 485)
PROFIBUS-DP
PROFIBUS-DP
PROFIBUS-PA
PROFIBUS-PA
EIB-2Y(St)Y
EIB-2Y(St)Y
EIB-H(St)H
EIB-H(St)H
  Language
Erse Kablo
PRODUCTS

Erline & Data Transmission Cables

Data Transmission Cables

Data transmission is the process of transfer data over a point-to-point or point-to-multipoint communication channel, like a communication medium to one or more computing, network, communication or electronic devices. Data transmission is also known as digital transmission or digital communications. The data are represented as an electromagnetic signal, such as an electrical voltage, radiowave, microwave, or infrared signal.

Data transfer rate is commonly measured in bits-per-second (bps), with one “bit” equal to an individual binary number. A wide range of different constructions of cables are available in order to cover data transmission needs in automation systems, computer networks and electronic control systems.

» Local Area Network Cables:

It is a computer network that links devices within a building or group of adjacent buildings, simply referred to as LAN Cables.
Computer networks, which provide the productivity and communication capabilities that will enable organizations to be successful, have now become the most important elements. Data transmission is significant for growing businesses, institutions and service providers to be able to build scalable networks that combine voice, video, data transfer and storage on an end-to-end intelligent network. All communication over a single infrastructure offers several advantages such as reduced costs, increased productivity and efficiency, elimination of the complexity of using separate networks, and scalability.

In order for the network systems to work fast and without problems, the cabling infrastructure must be well established. In network systems, there is no other interface that is used as long as the cabling infrastructure. The main reason for the preparation of structured cabling systems is to ensure that the network system grows without any problems. For this reason, a correct design and project should be done while creating the cabling infrastructure, quality workmanship and materials should be used, testing, labeling and documentation should be made in accordance with the standards and used for years.

There are generally three levels in structured cabling.
1. Floor distribution cabling (horizontal cabling)
2. Building distribution cabling (vertical cabling)
3. Campus (main) distribution cabling

ERLINE® branded Cat-5e U/UTP and Cat-6 U/UTP copper conductor data transmission cables that we produce as Erse Kablo are generally used in the horizontal cabling section of structured cabling. ERLINE® ethernet cables have been manufactured and certified according to IEC 61156-1 & -5 and ANSI/TIA 568-C.2.

» RS-485 Data Transmission Cables:

It is defined by EIA (USA Electronic Industry Association) as a two serial communication standard and more correctly named as EIA/TIA-485. Communication systems based on RS-485 communicate digital information over twisted pair wire from transmitters to receivers. Devices can be apart from each other up to 1220 meters without any repeaters and 32 RS-485 transceivers (32 drivers 32 receivers) can occupy a bus and communicate at rate from 100Kbps (at 1200 m) up to 10Mbps (at 12 m) varying by cable length. These systems utilize balanced outputs and differential inputs. As a result, they provide better noise immunity than single-ended systems such as RS-232. Thus, links using RS-485 operate over longer distance at higher speed than links using RS 232. RS-485 can be used in two and four-wire networked systems and tri-state capabilities of RS-485 transmitters enable multiple transceivers to be connected to a two-wire multidrop bus. Also, four-wire systems can be used master node driver to be connected to all slave receivers and all slave drivers to be connected to master receiver.

» Bus Data Transmission Cables:

Profibus is a data transmission system of host computer and other computers, sensors, motors, thermocouples, automatic valves which are parts of scada* system on a single line whereby high data speed, low connection costs and plug-and-play are central. It refers to the network protocols used for real-time distributed control. (*A generic name for systems that allow inspection, monitoring and operating under a logic of devices sprawling over a wide geographical area from a center by means of computers.)

There are two standard versions of BUS cables being producing in Erse Kablo. One of them is Profibus DP which stands for Decentralised Peripherals and the other is Profibus PA which stands for Process Automation.

Erse's Data Transmission Cable Solutions for the Customer Expectations

Our data transmission cables are produced for use in high-speed applications. It is focused on achieving the best possible electrical values.

Data Transmission Cables which have HFFR (Halogen Free Flame Retardant) sheathing are used in places where people are densely populated (such as hospitals, high residences, shopping centers, hotels etc.) and places in which it is required that there is no smoke and corrosive gases emitted by fire which threats to human health.

We are at your disposal for your demands; you could have best data transmission cable price from our export sales team and our technical team would be pleased to answer your questions about technical points. We will be happy to advise you on our product range and the possible applications of Erse’s data transmission cables. You can contact us with e-mail or head office’s telephone numbers.
ERLINE CAT-6 U/UTP
ERLINE CAT-6 U/UTP
ERLINE CAT-6 U/UTP LSZH
ERLINE CAT-6 U/UTP LSZH
ERLINE CAT-6 F/UTP
ERLINE CAT-6 F/UTP
ERLINE CAT-6 F/UTP LSZH
ERLINE CAT-6 F/UTP LSZH
LIY(St)Y PIMF
LIY(St)Y PIMF
LIY(St)CY PIMF
LIY(St)CY PIMF
LI2Y(St)Y PIMF
LI2Y(St)Y PIMF
LI2Y(St)CY PIMF
LI2Y(St)CY PIMF
LI2Y(St)CH PIMF
LI2Y(St)CH PIMF
LI2Y(St)H PIMF
LI2Y(St)H PIMF
LIH(St)H PIMF
LIH(St)H PIMF
LIH(St)CH PIMF
LIH(St)CH PIMF
LI2Y(St)CY PIMF (RS 232 - RS 422)
LI2Y(St)CY PIMF (RS 232 - RS 422)
LI2Y(St)CY (RS 485)
LI2Y(St)CY (RS 485)
PROFIBUS-DP
PROFIBUS-DP
PROFIBUS-PA
PROFIBUS-PA
EIB-2Y(St)Y
EIB-2Y(St)Y
EIB-H(St)H
EIB-H(St)H