Language
ÜRÜNLER
Ana Sayfa >  Enstruman Kabloları > Re-2g(st)hswah-pımf..cı > 

RE-2G(St)HSWAH-PIMF..CI

RE-2G(St)HSWAH-PIMF..CI

RE-2G(St)HSWAH-PIMF..CI

 
RE-2G(St)HSWAH-PIMF..CI
  • Indoor environments intensely populated by people where there is electromagnetic interference.
  • Instrumentation and control engineering analog and digital signal transmission
  • Petroleum refineries
  • Petrochemistry industry
  • Power plants
  • Natural gas pump stations
  • Dry-moist and wet places, at indoor
  • Gas Stations
  • Water Conveyance Systems
  • In applications where maintenance of circuit integrity in case of fire is required

NOTES

  • EMC*: Electromagnetic compatibility
  • CI*: Fire Resistant
  • Ral 5015 blue sheath*: At ex-proof connections in explosive and in flammable environments, intrinsically safe
  • Ral 9005 black sheath*: Places where UV resistance is required
  • Ral 2003 orange sheath*: Inside of buildings
Conductor IEC 60228 / DIN VDE 0295 / EN 60228
Insulation EN 50363-1 EI2 SILICONE
Colour code BS 5308-1 OR BLACK-WHITE EACH PAIR NUBERED
Individual Screen PES TAPE; TINNED DRAIN WIRE; AL-PES TAPE
Stranding PAIRWISE,SCREENED PAIRS IN LAYERS
Wrapping PES TAPE
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Inner Sheath EN 50290-2-27 LSZH COMPOUND
Armour GALVANIZED ROUND STEEL WIRES
Sheath EN 50290-2-27 LSZH COMPOUND
Sheath Colour RAL 5015* BLUE; RAL 9005* BLACK; RAL 2003* ORANGE OR RAL 3000* RED

CONDUCTOR
RESISTANCE
CLASS2(MAX)
INSULATION
RESISTANCE
(MIN)
MUTUAL
CAPACITY
(MAX)
TEMPERATURE
RANGE
FLAME
PROPAGATION
L/R(RATIO)
(MAX)
CURRENT
LOAD(25ºC)
mm²
0,50
0,75
1,0
1,3
1,5
Ω/km
36
24,5
18,1
13,9
12,1

MΩxKm

300

mm²
0,50
0,75
1,0
1,3
1,5
pF/m
150
150
150
150
150
-30ºC+90ºC
(FIXED LAYING)
IEC 60332-3-24
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24
mm²
0,50
0,75
1,0
1,3
1,5
µH/Ω
25
25
25
40
40
mm²
0,50
0,75
1,0
1,3
1,5
A
6,0
13
16
18
20
OPERATING
VOLTAGE
TEST
VOLTAGE
BENDING
RADIUS
SMOKE DENSITY TEST ON CORROSIVENESS
OF COMBUSTION GASES
HALOGEN
FREE TEST
FIRE RESISTANT
TEST
300/500 V. Cr./Cr.=2000 V
Cr./Scrn.=2000 V
10 X Cable Ø IEC 61034-2
VDE 0482-1034-2
EN 61034-2
BS EN 61034-2
IEC 60754-2
VDE 0482-267-2-3
EN 50267-2-3
BS EN 50267-2-3
IEC 60754-1
VDE 0482-267-2-1
EN 50267-2-1
BS EN 50267-2-1
IEC 60331-21
IEC 60331-23

CODE NR. NUMBER OF CORE
CROSS SECTION (
mm²)
COPPER WEIGHT
(kg/km)
INNER SHEATH
DIAMETER (mm)
OVERALL DIAMETER
(mm)
APPROX. WEIGHT
(kg/km)
STANDART LENGTH
(mt)
382450020 2 x 2 x 0,50 32 9,10 14,00 340 500/1000
382450040 4 x 2 x 0,50 60 10,60 15,70 430 500/1000
382450060 6 x 2 x 0,50 88 12,60 17,70 615 500/1000
382450080 8 x 2 x 0,50 115 13,70 18,80 700 500/1000
382450100 10 x 2 x 0,50 143 16,20 22,00 980 500/1000
382450120 12 x 2 x 0,50 170 16,60 22,50 1050 500/1000
382450160 16 x 2 x 0,50 225 18,50 24,70 1250 500/1000
382450200 20 x 2 x 0,50 280 20,70 27,00 1450 500/1000
382450240 24 x 2 x 0,50 336 23,00 30,00 1680 500/1000
             
382475020 2 x 2 x 0,75 42 9,80 14,50 370 500/1000
382475040 4 x 2 x 0,75 79 11,40 16,50 475 500/1000
382475060 6 x 2 x 0,75 116 13,80 18,80 615 500/1000
382475080 8 x 2 x 0,75 154 14,80 20,00 700 500/1000
382475100 10 x 2 x 0,75 191 17,50 24,00 980 500/1000
382475120 12 x 2 x 0,75 228 18,20 24,50 1050 500/1000
382475160 16 x 2 x 0,75 302 20,50 26,50 1250 500/1000
382475200 20 x 2 x 0,75 377 22,50 29,00 1450 500/1000
382475240 24 x 2 x 0,75 451 25,20 32,00 1680 500/1000
             
382401020 2 x 2 x 1 51 10,50 15,50 411 500/1000
382401040 4 x 2 x 1 98 12,30 17,50 530 500/1000
382401060 6 x 2 x 1 145 14,80 20,00 695 500/1000
382401080 8 x 2 x 1 192 16,20 21,50 895 500/1000
382401100 10 x 2 x 1 239 19,00 25,00 1085 500/1000
382401120 12 x 2 x 1 285 19,60 26,00 1180 500/1000
382401160 16 x 2 x 1 379 21,80 28,20 1415 500/1000
382401200 20 x 2 x 1 473 24,50 31,00 1670 500/1000
382401240 24 x 2 x 1 566 27,40 35,00 2130 500/1000
             
382413020 2 x 2 x 1,3 63 11,30 16,50 455 500/1000
382413040 4 x 2 x 1,3 120 13,20 18,00 580 500/1000
382413060 6 x 2 x 1,3 179 15,90 21,00 875 500/1000
382413080 8 x 2 x 1,3 237 17,40 23,50 1010 500/1000
382413100 10 x 2 x 1,3 295 20,50 26,50 1210 500/1000
382413120 12 x 2 x 1,3 353 21,00 27,50 1320 500/1000
382413160 16 x 2 x 1,3 467 23,50 30,00 1600 500/1000
382413200 20 x 2 x 1,3 585 26,50 34,00 2050 500/1000
382413240 24 x 2 x 1,3 700 30,00 37,50 2420 500/1000
             
382415020 2 x 2 x 1,5 70 11,70 16,80 470 500/1000
382415040 4 x 2 x 1,5 135 14,00 19,00 615 500/1000
382415060 6 x 2 x 1,5 200 16,50 22,50 925 500/1000
382415080 8 x 2 x 1,5 265 18,00 24,00 1060 500/1000
382415100 10 x 2 x 1,5 331 21,00 27,50 1300 500/1000
382415120 12 x 2 x 1,5 396 22,00 28,00 1470 500/1000
382415160 16 x 2 x 1,5 526 24,50 31,00 1715 500/1000
382415200 20 x 2 x 1,5 657 27,50 35,00 2221 500/1000
382415240 24 x 2 x 1,5 787 31,00 39,00 2600 500/1000

Erse Kablo
Türkçe English
ÜRÜNLER

RE-2G(St)HSWAH-PIMF..CI

RE-2G(St)HSWAH-PIMF..CI

RE-2G(St)HSWAH-PIMF..CI

 
  • Indoor environments intensely populated by people where there is electromagnetic interference.
  • Instrumentation and control engineering analog and digital signal transmission
  • Petroleum refineries
  • Petrochemistry industry
  • Power plants
  • Natural gas pump stations
  • Dry-moist and wet places, at indoor
  • Gas Stations
  • Water Conveyance Systems
  • In applications where maintenance of circuit integrity in case of fire is required
Conductor IEC 60228 / DIN VDE 0295 / EN 60228
Insulation EN 50363-1 EI2 SILICONE
Colour code BS 5308-1 OR BLACK-WHITE EACH PAIR NUBERED
Individual Screen PES TAPE; TINNED DRAIN WIRE; AL-PES TAPE
Stranding PAIRWISE,SCREENED PAIRS IN LAYERS
Wrapping PES TAPE
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Inner Sheath EN 50290-2-27 LSZH COMPOUND
Armour GALVANIZED ROUND STEEL WIRES
Sheath EN 50290-2-27 LSZH COMPOUND
Sheath Colour RAL 5015* BLUE; RAL 9005* BLACK; RAL 2003* ORANGE OR RAL 3000* RED
CONDUCTOR
RESISTANCE
CLASS2(MAX)
INSULATION
RESISTANCE
(MIN)
MUTUAL
CAPACITY
(MAX)
TEMPERATURE
RANGE
FLAME
PROPAGATION
L/R(RATIO)
(MAX)
CURRENT
LOAD(25ºC)
mm²
0,50
0,75
1,0
1,3
1,5
Ω/km
36
24,5
18,1
13,9
12,1

MΩxKm

300

mm²
0,50
0,75
1,0
1,3
1,5
pF/m
150
150
150
150
150
-30ºC+90ºC
(FIXED LAYING)
IEC 60332-3-24
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24
mm²
0,50
0,75
1,0
1,3
1,5
µH/Ω
25
25
25
40
40
mm²
0,50
0,75
1,0
1,3
1,5
A
6,0
13
16
18
20
OPERATING
VOLTAGE
TEST
VOLTAGE
BENDING
RADIUS
SMOKE DENSITY TEST ON CORROSIVENESS
OF COMBUSTION GASES
HALOGEN
FREE TEST
FIRE RESISTANT
TEST
300/500 V. Cr./Cr.=2000 V
Cr./Scrn.=2000 V
10 X Cable Ø IEC 61034-2
VDE 0482-1034-2
EN 61034-2
BS EN 61034-2
IEC 60754-2
VDE 0482-267-2-3
EN 50267-2-3
BS EN 50267-2-3
IEC 60754-1
VDE 0482-267-2-1
EN 50267-2-1
BS EN 50267-2-1
IEC 60331-21
IEC 60331-23

CODE NR. NUMBER OF CORE
CROSS SECTION (
mm²)
COPPER WEIGHT
(kg/km)
INNER SHEATH
DIAMETER (mm)
OVERALL DIAMETER
(mm)
APPROX. WEIGHT
(kg/km)
STANDART LENGTH
(mt)
382450020 2 x 2 x 0,50 32 9,10 14,00 340 500/1000
382450040 4 x 2 x 0,50 60 10,60 15,70 430 500/1000
382450060 6 x 2 x 0,50 88 12,60 17,70 615 500/1000
382450080 8 x 2 x 0,50 115 13,70 18,80 700 500/1000
382450100 10 x 2 x 0,50 143 16,20 22,00 980 500/1000
382450120 12 x 2 x 0,50 170 16,60 22,50 1050 500/1000
382450160 16 x 2 x 0,50 225 18,50 24,70 1250 500/1000
382450200 20 x 2 x 0,50 280 20,70 27,00 1450 500/1000
382450240 24 x 2 x 0,50 336 23,00 30,00 1680 500/1000
             
382475020 2 x 2 x 0,75 42 9,80 14,50 370 500/1000
382475040 4 x 2 x 0,75 79 11,40 16,50 475 500/1000
382475060 6 x 2 x 0,75 116 13,80 18,80 615 500/1000
382475080 8 x 2 x 0,75 154 14,80 20,00 700 500/1000
382475100 10 x 2 x 0,75 191 17,50 24,00 980 500/1000
382475120 12 x 2 x 0,75 228 18,20 24,50 1050 500/1000
382475160 16 x 2 x 0,75 302 20,50 26,50 1250 500/1000
382475200 20 x 2 x 0,75 377 22,50 29,00 1450 500/1000
382475240 24 x 2 x 0,75 451 25,20 32,00 1680 500/1000
             
382401020 2 x 2 x 1 51 10,50 15,50 411 500/1000
382401040 4 x 2 x 1 98 12,30 17,50 530 500/1000
382401060 6 x 2 x 1 145 14,80 20,00 695 500/1000
382401080 8 x 2 x 1 192 16,20 21,50 895 500/1000
382401100 10 x 2 x 1 239 19,00 25,00 1085 500/1000
382401120 12 x 2 x 1 285 19,60 26,00 1180 500/1000
382401160 16 x 2 x 1 379 21,80 28,20 1415 500/1000
382401200 20 x 2 x 1 473 24,50 31,00 1670 500/1000
382401240 24 x 2 x 1 566 27,40 35,00 2130 500/1000
             
382413020 2 x 2 x 1,3 63 11,30 16,50 455 500/1000
382413040 4 x 2 x 1,3 120 13,20 18,00 580 500/1000
382413060 6 x 2 x 1,3 179 15,90 21,00 875 500/1000
382413080 8 x 2 x 1,3 237 17,40 23,50 1010 500/1000
382413100 10 x 2 x 1,3 295 20,50 26,50 1210 500/1000
382413120 12 x 2 x 1,3 353 21,00 27,50 1320 500/1000
382413160 16 x 2 x 1,3 467 23,50 30,00 1600 500/1000
382413200 20 x 2 x 1,3 585 26,50 34,00 2050 500/1000
382413240 24 x 2 x 1,3 700 30,00 37,50 2420 500/1000
             
382415020 2 x 2 x 1,5 70 11,70 16,80 470 500/1000
382415040 4 x 2 x 1,5 135 14,00 19,00 615 500/1000
382415060 6 x 2 x 1,5 200 16,50 22,50 925 500/1000
382415080 8 x 2 x 1,5 265 18,00 24,00 1060 500/1000
382415100 10 x 2 x 1,5 331 21,00 27,50 1300 500/1000
382415120 12 x 2 x 1,5 396 22,00 28,00 1470 500/1000
382415160 16 x 2 x 1,5 526 24,50 31,00 1715 500/1000
382415200 20 x 2 x 1,5 657 27,50 35,00 2221 500/1000
382415240 24 x 2 x 1,5 787 31,00 39,00 2600 500/1000
Türkçe English
Erse Kablo
ÜRÜNLER

RE-2G(St)HSWAH-PIMF..CI

RE-2G(St)HSWAH-PIMF..CI

RE-2G(St)HSWAH-PIMF..CI

 
  • Indoor environments intensely populated by people where there is electromagnetic interference.
  • Instrumentation and control engineering analog and digital signal transmission
  • Petroleum refineries
  • Petrochemistry industry
  • Power plants
  • Natural gas pump stations
  • Dry-moist and wet places, at indoor
  • Gas Stations
  • Water Conveyance Systems
  • In applications where maintenance of circuit integrity in case of fire is required
Conductor IEC 60228 / DIN VDE 0295 / EN 60228
Insulation EN 50363-1 EI2 SILICONE
Colour code BS 5308-1 OR BLACK-WHITE EACH PAIR NUBERED
Individual Screen PES TAPE; TINNED DRAIN WIRE; AL-PES TAPE
Stranding PAIRWISE,SCREENED PAIRS IN LAYERS
Wrapping PES TAPE
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Inner Sheath EN 50290-2-27 LSZH COMPOUND
Armour GALVANIZED ROUND STEEL WIRES
Sheath EN 50290-2-27 LSZH COMPOUND
Sheath Colour RAL 5015* BLUE; RAL 9005* BLACK; RAL 2003* ORANGE OR RAL 3000* RED
CONDUCTOR
RESISTANCE
CLASS2(MAX)
INSULATION
RESISTANCE
(MIN)
MUTUAL
CAPACITY
(MAX)
TEMPERATURE
RANGE
FLAME
PROPAGATION
L/R(RATIO)
(MAX)
CURRENT
LOAD(25ºC)
mm²
0,50
0,75
1,0
1,3
1,5
Ω/km
36
24,5
18,1
13,9
12,1

MΩxKm

300

mm²
0,50
0,75
1,0
1,3
1,5
pF/m
150
150
150
150
150
-30ºC+90ºC
(FIXED LAYING)
IEC 60332-3-24
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24
mm²
0,50
0,75
1,0
1,3
1,5
µH/Ω
25
25
25
40
40
mm²
0,50
0,75
1,0
1,3
1,5
A
6,0
13
16
18
20
OPERATING
VOLTAGE
TEST
VOLTAGE
BENDING
RADIUS
SMOKE DENSITY TEST ON CORROSIVENESS
OF COMBUSTION GASES
HALOGEN
FREE TEST
FIRE RESISTANT
TEST
300/500 V. Cr./Cr.=2000 V
Cr./Scrn.=2000 V
10 X Cable Ø IEC 61034-2
VDE 0482-1034-2
EN 61034-2
BS EN 61034-2
IEC 60754-2
VDE 0482-267-2-3
EN 50267-2-3
BS EN 50267-2-3
IEC 60754-1
VDE 0482-267-2-1
EN 50267-2-1
BS EN 50267-2-1
IEC 60331-21
IEC 60331-23

CODE NR. NUMBER OF CORE
CROSS SECTION (
mm²)
COPPER WEIGHT
(kg/km)
INNER SHEATH
DIAMETER (mm)
OVERALL DIAMETER
(mm)
APPROX. WEIGHT
(kg/km)
STANDART LENGTH
(mt)
382450020 2 x 2 x 0,50 32 9,10 14,00 340 500/1000
382450040 4 x 2 x 0,50 60 10,60 15,70 430 500/1000
382450060 6 x 2 x 0,50 88 12,60 17,70 615 500/1000
382450080 8 x 2 x 0,50 115 13,70 18,80 700 500/1000
382450100 10 x 2 x 0,50 143 16,20 22,00 980 500/1000
382450120 12 x 2 x 0,50 170 16,60 22,50 1050 500/1000
382450160 16 x 2 x 0,50 225 18,50 24,70 1250 500/1000
382450200 20 x 2 x 0,50 280 20,70 27,00 1450 500/1000
382450240 24 x 2 x 0,50 336 23,00 30,00 1680 500/1000
             
382475020 2 x 2 x 0,75 42 9,80 14,50 370 500/1000
382475040 4 x 2 x 0,75 79 11,40 16,50 475 500/1000
382475060 6 x 2 x 0,75 116 13,80 18,80 615 500/1000
382475080 8 x 2 x 0,75 154 14,80 20,00 700 500/1000
382475100 10 x 2 x 0,75 191 17,50 24,00 980 500/1000
382475120 12 x 2 x 0,75 228 18,20 24,50 1050 500/1000
382475160 16 x 2 x 0,75 302 20,50 26,50 1250 500/1000
382475200 20 x 2 x 0,75 377 22,50 29,00 1450 500/1000
382475240 24 x 2 x 0,75 451 25,20 32,00 1680 500/1000
             
382401020 2 x 2 x 1 51 10,50 15,50 411 500/1000
382401040 4 x 2 x 1 98 12,30 17,50 530 500/1000
382401060 6 x 2 x 1 145 14,80 20,00 695 500/1000
382401080 8 x 2 x 1 192 16,20 21,50 895 500/1000
382401100 10 x 2 x 1 239 19,00 25,00 1085 500/1000
382401120 12 x 2 x 1 285 19,60 26,00 1180 500/1000
382401160 16 x 2 x 1 379 21,80 28,20 1415 500/1000
382401200 20 x 2 x 1 473 24,50 31,00 1670 500/1000
382401240 24 x 2 x 1 566 27,40 35,00 2130 500/1000
             
382413020 2 x 2 x 1,3 63 11,30 16,50 455 500/1000
382413040 4 x 2 x 1,3 120 13,20 18,00 580 500/1000
382413060 6 x 2 x 1,3 179 15,90 21,00 875 500/1000
382413080 8 x 2 x 1,3 237 17,40 23,50 1010 500/1000
382413100 10 x 2 x 1,3 295 20,50 26,50 1210 500/1000
382413120 12 x 2 x 1,3 353 21,00 27,50 1320 500/1000
382413160 16 x 2 x 1,3 467 23,50 30,00 1600 500/1000
382413200 20 x 2 x 1,3 585 26,50 34,00 2050 500/1000
382413240 24 x 2 x 1,3 700 30,00 37,50 2420 500/1000
             
382415020 2 x 2 x 1,5 70 11,70 16,80 470 500/1000
382415040 4 x 2 x 1,5 135 14,00 19,00 615 500/1000
382415060 6 x 2 x 1,5 200 16,50 22,50 925 500/1000
382415080 8 x 2 x 1,5 265 18,00 24,00 1060 500/1000
382415100 10 x 2 x 1,5 331 21,00 27,50 1300 500/1000
382415120 12 x 2 x 1,5 396 22,00 28,00 1470 500/1000
382415160 16 x 2 x 1,5 526 24,50 31,00 1715 500/1000
382415200 20 x 2 x 1,5 657 27,50 35,00 2221 500/1000
382415240 24 x 2 x 1,5 787 31,00 39,00 2600 500/1000
Türkçe English
Erse Kablo
ÜRÜNLER

RE-2G(St)HSWAH-PIMF..CI

RE-2G(St)HSWAH-PIMF..CI

RE-2G(St)HSWAH-PIMF..CI

 
  • Indoor environments intensely populated by people where there is electromagnetic interference.
  • Instrumentation and control engineering analog and digital signal transmission
  • Petroleum refineries
  • Petrochemistry industry
  • Power plants
  • Natural gas pump stations
  • Dry-moist and wet places, at indoor
  • Gas Stations
  • Water Conveyance Systems
  • In applications where maintenance of circuit integrity in case of fire is required
Conductor IEC 60228 / DIN VDE 0295 / EN 60228
Insulation EN 50363-1 EI2 SILICONE
Colour code BS 5308-1 OR BLACK-WHITE EACH PAIR NUBERED
Individual Screen PES TAPE; TINNED DRAIN WIRE; AL-PES TAPE
Stranding PAIRWISE,SCREENED PAIRS IN LAYERS
Wrapping PES TAPE
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Inner Sheath EN 50290-2-27 LSZH COMPOUND
Armour GALVANIZED ROUND STEEL WIRES
Sheath EN 50290-2-27 LSZH COMPOUND
Sheath Colour RAL 5015* BLUE; RAL 9005* BLACK; RAL 2003* ORANGE OR RAL 3000* RED
CONDUCTOR
RESISTANCE
CLASS2(MAX)
INSULATION
RESISTANCE
(MIN)
MUTUAL
CAPACITY
(MAX)
TEMPERATURE
RANGE
FLAME
PROPAGATION
L/R(RATIO)
(MAX)
CURRENT
LOAD(25ºC)
mm²
0,50
0,75
1,0
1,3
1,5
Ω/km
36
24,5
18,1
13,9
12,1

MΩxKm

300

mm²
0,50
0,75
1,0
1,3
1,5
pF/m
150
150
150
150
150
-30ºC+90ºC
(FIXED LAYING)
IEC 60332-3-24
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24
mm²
0,50
0,75
1,0
1,3
1,5
µH/Ω
25
25
25
40
40
mm²
0,50
0,75
1,0
1,3
1,5
A
6,0
13
16
18
20
OPERATING
VOLTAGE
TEST
VOLTAGE
BENDING
RADIUS
SMOKE DENSITY TEST ON CORROSIVENESS
OF COMBUSTION GASES
HALOGEN
FREE TEST
FIRE RESISTANT
TEST
300/500 V. Cr./Cr.=2000 V
Cr./Scrn.=2000 V
10 X Cable Ø IEC 61034-2
VDE 0482-1034-2
EN 61034-2
BS EN 61034-2
IEC 60754-2
VDE 0482-267-2-3
EN 50267-2-3
BS EN 50267-2-3
IEC 60754-1
VDE 0482-267-2-1
EN 50267-2-1
BS EN 50267-2-1
IEC 60331-21
IEC 60331-23

CODE NR. NUMBER OF CORE
CROSS SECTION (
mm²)
COPPER WEIGHT
(kg/km)
INNER SHEATH
DIAMETER (mm)
OVERALL DIAMETER
(mm)
APPROX. WEIGHT
(kg/km)
STANDART LENGTH
(mt)
382450020 2 x 2 x 0,50 32 9,10 14,00 340 500/1000
382450040 4 x 2 x 0,50 60 10,60 15,70 430 500/1000
382450060 6 x 2 x 0,50 88 12,60 17,70 615 500/1000
382450080 8 x 2 x 0,50 115 13,70 18,80 700 500/1000
382450100 10 x 2 x 0,50 143 16,20 22,00 980 500/1000
382450120 12 x 2 x 0,50 170 16,60 22,50 1050 500/1000
382450160 16 x 2 x 0,50 225 18,50 24,70 1250 500/1000
382450200 20 x 2 x 0,50 280 20,70 27,00 1450 500/1000
382450240 24 x 2 x 0,50 336 23,00 30,00 1680 500/1000
             
382475020 2 x 2 x 0,75 42 9,80 14,50 370 500/1000
382475040 4 x 2 x 0,75 79 11,40 16,50 475 500/1000
382475060 6 x 2 x 0,75 116 13,80 18,80 615 500/1000
382475080 8 x 2 x 0,75 154 14,80 20,00 700 500/1000
382475100 10 x 2 x 0,75 191 17,50 24,00 980 500/1000
382475120 12 x 2 x 0,75 228 18,20 24,50 1050 500/1000
382475160 16 x 2 x 0,75 302 20,50 26,50 1250 500/1000
382475200 20 x 2 x 0,75 377 22,50 29,00 1450 500/1000
382475240 24 x 2 x 0,75 451 25,20 32,00 1680 500/1000
             
382401020 2 x 2 x 1 51 10,50 15,50 411 500/1000
382401040 4 x 2 x 1 98 12,30 17,50 530 500/1000
382401060 6 x 2 x 1 145 14,80 20,00 695 500/1000
382401080 8 x 2 x 1 192 16,20 21,50 895 500/1000
382401100 10 x 2 x 1 239 19,00 25,00 1085 500/1000
382401120 12 x 2 x 1 285 19,60 26,00 1180 500/1000
382401160 16 x 2 x 1 379 21,80 28,20 1415 500/1000
382401200 20 x 2 x 1 473 24,50 31,00 1670 500/1000
382401240 24 x 2 x 1 566 27,40 35,00 2130 500/1000
             
382413020 2 x 2 x 1,3 63 11,30 16,50 455 500/1000
382413040 4 x 2 x 1,3 120 13,20 18,00 580 500/1000
382413060 6 x 2 x 1,3 179 15,90 21,00 875 500/1000
382413080 8 x 2 x 1,3 237 17,40 23,50 1010 500/1000
382413100 10 x 2 x 1,3 295 20,50 26,50 1210 500/1000
382413120 12 x 2 x 1,3 353 21,00 27,50 1320 500/1000
382413160 16 x 2 x 1,3 467 23,50 30,00 1600 500/1000
382413200 20 x 2 x 1,3 585 26,50 34,00 2050 500/1000
382413240 24 x 2 x 1,3 700 30,00 37,50 2420 500/1000
             
382415020 2 x 2 x 1,5 70 11,70 16,80 470 500/1000
382415040 4 x 2 x 1,5 135 14,00 19,00 615 500/1000
382415060 6 x 2 x 1,5 200 16,50 22,50 925 500/1000
382415080 8 x 2 x 1,5 265 18,00 24,00 1060 500/1000
382415100 10 x 2 x 1,5 331 21,00 27,50 1300 500/1000
382415120 12 x 2 x 1,5 396 22,00 28,00 1470 500/1000
382415160 16 x 2 x 1,5 526 24,50 31,00 1715 500/1000
382415200 20 x 2 x 1,5 657 27,50 35,00 2221 500/1000
382415240 24 x 2 x 1,5 787 31,00 39,00 2600 500/1000
Erse Kablo Erse Kablo Erse Kablo Erse Kablo Erse Kablo Erse Kablo